Menu
  • Home
  • Applications
    • Potable Water Applications
    • Industrial Applications
    • Environmental Applications
    • Wastewater Applications
  • Products
    • proSONDE Multiparameter Sonde
    • Proteus Multiparameter Sensor
    • Multiparameter Sensor Accessories
    • Data Buoys
    • Telemetry Systems
  • Parameters
    • Fluorescence
      • Blue-Green Algae
      • BOD
      • CDOM
      • COD
      • Chlorophyll A
      • Coliforms (Faecal, E.coli, Total)
      • Crude Oil
      • DOC & TOC
      • Fluorescein Dye
      • Optical Brighteners
      • Refined Oils
      • Rhodamine Dye
      • Tryptophan
    • Physiochemical
      • Dissolved Oxygen
      • EC, Salinity & TDS
      • ORP/REDOX
      • pH
      • Temperature
      • Turbidity
    • ISEs
      • Ammonium & Ammonia
      • Bromide
      • Calcium
      • Chloride
      • Nitrates
      • Sodium
  • Services
    • Consultancy Services
    • Installation Services
    • Calibration Services
    • Training Services
    • Maintenance Services
    • Data Only Services
    • Rental Services
    • Support Resources
  • About Us
    • Contact Us
    • Case Studies
    • News
    • Scientific Papers
    • Podcasts
    • Webinars
    • International Distributors
    • Events
    • Legal
  •   Cart
  • Home

  • Applications

    • Potable Water Applications
    • Industrial Applications
    • Environmental Applications
    • Wastewater Applications
  • Products

    • proSONDE Multiparameter Sonde
    • Proteus Multiparameter Sensor
    • Multiparameter Sensor Accessories
    • Data Buoys
    • Telemetry Systems
  • Parameters

    • Fluorescence
    • Physiochemical
    • ISEs
  • Services

    • Consultancy Services
    • Installation Services
    • Calibration Services
    • Training Services
    • Maintenance Services
    • Data Only Services
    • Rental Services
    • Support Resources
  • About Us

    • Contact Us
    • Case Studies
    • News
    • Scientific Papers
    • Podcasts
    • Webinars
    • International Distributors
    • Events
    • Legal
  • Cart

Home  >  proSONDE® Multiparameter Sonde

proSONDE Multiparameter Sonde

New
  • Superior Anti-fouling Flush mount sensors, copper bulkhead, copper mesh and plug and play wiper
  • Unlimited Integration With USB, modbus, RS232/RS485 and SDI12 comms connectivity is straightforward. Bluetooth Connectivity.
  • Plug and Play Sensors Install any digital sensor in any port in seconds; no complex tooling, no fuss. Change our USB sensors on the fly, keeping your system running smoothly without interruption.
Product Options
Cart is updated.
Cart is updated.

Overview

proSONDE® is a fully customisable 11-port sonde and the first instrument in the world to incorporate our patent-pending UV-AF technology; full spectrum absorbance and fluorescence marking an unprecedented leap into the future.

proSONDE® also features our exclusive proFLUOR fluorometers, flat-faced sensors, superior levels of anti-fouling, algorithm builder and industry-leading software with Bluetooth connectivity.

This is more than just a sensor; it’s a world-first innovation built for water quality professionals exuding precision, performance and reliability.

Manufactured by: Proteus Instruments
Model: proSONDE® Multiparameter Sonde

Services offered for this product

  • Sales
  • Rental
  • Installation
  • Calibration
  • Maintenance
  • IoT Cloud Compatible

Specification

BOD

BOD Parameter Specifications
Units BOD mg/l
Range** 0-2000 mg/l
Resolution 0.01 mg/l
Accuracy ±5 % of reading*
Comments Local site calibration can improve accuracy.

Coliform Counts

Coliform Counts Parameter Specifications
Units CFU/100 m
Range** >1 count/100ml
Resolution 1 count/100ml
Accuracy ±10 Coliforms*
Comments Local site calibration can improve accuracy.
Can be used for faecal coliforms, E. coli or total coliforms

COD

COD Parameter Specifications
Units COD mg/l
Range** 0-4000 mg/l
Resolution 0.01 mg/l
Accuracy ±5 % of reading*
Comments Local site calibration can improve accuracy.

DOC

DOC Parameter Specifications
Units DOC mg/l
Range** 0-3000 mg/l
Resolution 0.01 mg/l
Accuracy ±5 % of reading*
Comments Local site calibration can improve accuracy.

TOC

DOC Parameter Specifications
Units DOC mg/l
Range** 0-3000 mg/l
Resolution 0.01 mg/l
Accuracy ±5 % of reading*
Comments Local site calibration can improve accuracy.

Ammonium (Optical or ISE)

Ammonium Parameter Specifications
Units NH4
Range** 0-200 mg/l
Resolution 0.01 mg/l
Accuracy ±0.1 mg/l 0 - 10 mg/l*
±0.5 mg/l 10 - 200 mg/l*
Comments Environmental/river applications typically 0 - 2 mg/l
Wastewater applications typically 0 - 50 mg/l

Phosphate

Phosphate Parameter Specifications
Units PO4
Range** 0-100 mg/l
Resolution 0.01 mg/l
Accuracy ±0.1 mg/l 0 - 2 mg/l*
±0.5 mg/l 2 - 100 mg/l*
Comments Environmental/river applications typically 0 - 1 mg/l
Wastewater applications typically 0 - 50 mg/l

TSS

Total Suspended Solids (TSS) Parameter Specifications
Units TSS mg/l
Range** 0-10,000 mg/l
Resolution 0.1 mg/l
Accuracy ±2 % of reading or 0.2*
Comments Calculated using the correlation between turbidity and a sediment standard or sample. Local calibration can be applied.

General Specifications

Internal Power Battery Life 1 to 24 month depending on sensors / logging rates
External Power 5-15 vdc
Operating Temperature -5 to 50°C, non-freezing
Calibrated Range 0 to 40°C
Depth Rating 100 m
Communications USB, RS232, Modbus®, SDI-12 as standard.
Sample Rate 1 Hz
Data Memory 64 Gb removable SD card
Logging Rates 1 second to 1 day
Warranty 2 years (All sensors excluding ISE's)
Diameter 90 mm (3.5")
Length (w/o battery pack) 460 mm (18.11")
Material Acetate/Polycarbonate
Typical Weight 1.97 kg (4.34 lbs)
Number of Sensors Up to 11
Internal Battery Pack 5000 mAh

Temperature

Units Water Temperature
Range** -5 to 50°C
Resolution 0.01
Accuracy ±0.01°C
Comments Never needs calibration

pH

Units pH
Range** 0 to 13 units
Resolution 0.01
Accuracy ±0.1 within 10°C of calibration, 0.2°C otherwise
Comments Refillable reference electrode; corrected for temperature; typical sensor life > 4 years.

ORP

Units ORP
Range** -999 to 999 mV
Resolution ±0.05
Accuracy ±20 mV
Comments Platinum ORP sensor is combined with pH sensor.

Turbidity

Units Turbidity
Range** 0-4000 NTU
Resolution 4 digits max 2 d.p.
Accuracy ±2 % of reading or 0.2
Comments Compensated for temperature; filtered for non-turbidity spikes; includes wiper to clean the optics.

Optical Dissolved Oxygen

Units Concentration
Range** 0 to 50 mg/l
Resolution 0.01
Accuracy ±0.1
Comments Compensated for temperature and salinity; EPA approved "lifetime" luminescence method;

Units % saturation
Range** 0 to 500 % saturation
Resolution 0.1 %
Accuracy Corresponds with the accuracy of the concentration reading
Comments Compensated for temperature and salinity; EPA approved "lifetime" luminescence method;

Conductivity

Units Specific conductance µS/cm
Range** 1 µS to mS/cm
Resolution 0.1
Accuracy ±0.5% of reading upto 5000 µS
±2 % thereafter
Comments Corrected for temperature; four easy-to-clean graphite electrodes.

 

Units Salinity
Range** 0 to 70 PSU
Resolution 0.01
Accuracy ±2 % of reading
Comments Calculated from specific conductance.
PSU = Practical Salinity Units which is equivalent to ppt.

 

Fluorometers

  Range**
CDOM/fDOM 0.6 to 2000 ppb
Chlorophyll a
(red excitation)
0 to 500 µg/l
Chlorophyll b
(blue excitation)
0 to 500 µg/l
Tryptophan 0 to 2000 ppb
Resolution (all fluorometers) 4 digits max 2 d.p.
Accuracy (all fluorometers)

Linearity of 0.99R2(temperature compensated 0-50°C)

Accuracy ±0.5 ppb

Comments (all fluorometers) Highest-quality LED fluorometric sensors rated to 100 m depth same as depth sensor.

Ion-selective electrodes (ISE's)

  Range**
Ammonium 0 to 100 mg/l as nitrogen
Nitrate 0.1 to 14,000 ppm as nitrogen
Chloride 1.8 to 35,500 ppm
Sodium*** 0 to 20,000 mg/l
Calcium*** 0 to 40,000 mg/l
Bromide*** 0 to 80,000 mg/l
Resolution (all ISE's) 0.1
Accuracy (all fluorometers)

±2 mg/l or ±5 % whichever is the greater

Comments (all fluorometers) Corrected for ionic strength (via conductivity readings); the accuracy specification relies on non-trivial maintenance practice and frequent calibration near the temperature of measurement; ammonium and nitrate require tip replacement every 3 - 6 months. Please contact us for applications > 10 m.

 

*Providing local adequate field calibration

**Customised ranges are available

***Q2 2026

Downloads

Data Sheet
  • APPLICATIONS

    Wastewater
    Industrial
    Environmental
    Potable

  • HELPFUL LINKS

    Support Resources
    International Distributors
    Case Studies
    News
    Contact

  • CONTACT US

    UK & WORLDWIDE
    info@proteus-instruments.com
    Tel: +44 (0) 1527 433221

  • FOLLOW US

    • LinkedIn
    • YouTube
    • Instagram
    Subscribe to Newsletter

© Copyright Proteus Instruments

Please call us on +44(0) 1527 882060 if your requirement is urgent or continue with the quote cart.
Bundle